Procal Analytics Ltd. was formed in 1985 by a group of specialists with substantial experience in the development, manufacture and marketing of process analyzers and of the demands of today's industrial processes. Procal produces a range of analyzers capable of measuring, with superior performance, a full range of components on-line in aggressive environments often encountered in today's industry.

   
     
Click on MCERTS logo
for more information
 
 
 
 
ACWn
Procal 5000
Pulsi 200LR
 

  APPLICATIONS FOR PROCAL ANALYTICAL INSTRUMENTS  
         PROCESS          POWER

 
 
 

 
Procal Analytics have several instruments used in process analysis. Whenever possible, the analysis is done in situ, thereby avoiding the need to extract and handle a process sample. The example below is just one of many which Procal Analytics have proved to be very successful demonstrating the versatility of process analysers.
By utilising multiple wavelength and chemometric methods, it is possible to monitor components which exhibit cross sensitivity to each other.
 
Procal Analytics make a range of stack gas analysers to meet the continuous emission monitoring (CEM) requirements of fossil fuelled power stations. The analysers are in situ and can be automatically zero and calibrated to ensure compliance with local Environmental Agency requirements.
For example - US EPA 4OCFR Part 60 and 75.
The instruments are capable of monitoring, simultaneously, up to six components.
 
  Continuous Emission Monitoring of Flue Gases   Example analyser ranges:  
  Examples:

Chlorine and Ferric Chloride in EDC

PULSI 620:
Range 1: 50ppm, Cl2
Range 2: 100ppm, Ferric Chloride.

Ammonia Nitrate Plant
Gas NO range 1: 360ppm NO
Gas NO-2 range 2: 7200ppm NO
Gas NO-3 range 3: 28800ppm NO
Gas N2O: 400ppm N2O
Gas CO2: 16000ppm CO2
Gas CH4: 6400ppm CH4
 
Coal Fired
Power Station

Gas Turbine
Power Station

Coal Fired
Power Station
 
   
Pulsi 200LR
Procal 5000
Procal 5000
 
    Range 1: 200ppm, SO2
Range 2: 200ppm, NO
Range 3: 200ppm, CO
Range 4: 12%, CO2
Range 5: 12%, H2O
Range 1: 20ppm, NO
Range 2: 20ppm, NO2
Range3: 20ppm, SO2
Range 1: 20ppm, NH3
Range 2: 50ppm, NO
Range 3: 50ppm, N02
Range 4: 100ppm, S02
 
   
Other components typically measured in power stations include hydrocarbons and NO2. The examples above are of our continuous emission monitoring (CEM) analyzers. The instruments will be calibrated to our customer's requirements, therefore the selection and ranges of the components to be measured will be dependent on the customers requirements.
 

         PROCESS INSTALLATIONS          POWER INSTALLATIONS
Nitric Acid Plants, Dyno Nobel, Maitland, Ontario
Incinerators, ECO Waste Solutions, Dorchester, Ontario
Ammonia Nitrate, SaskFerco, Saskatchewan
    Power Boiler, City of Toronto
Power Boiler, CFB, Gagetown
CoGen Power, AbitibiBowater, Fort Frances
 

 
 

 

 
 

  Analyzer Control Unit (ACU) for Windows    

This control room software package (ACWn)
can be used by all Procal analysers.


It can be the basis of a complete CEM system. The program can be    configured to collect data from up to 8 analysers, each of which can    accept 4-20mA inputs from other instruments.
Trend storage for up to 5 years
Daily, weekly and monthly report options

 
 
        
 
 
  Procal 5000    
 


Typical applications:
Very low-level SOX, NOX; Ammonia slip and Total Reduced Sulphur (TRS)


The Procal 5000 range of CEM (Continuous Emissions Monitoring) instruments is designed for in stack analysis of up to 6 gas phase stack emission components.

Measurement principle: Full UV spectrum analysis, coupled with    Enveloped Folded Beam
Fast response by direct in site measurement
Low maintenance
 
     
 
 
Pulsi 200LR      







NOW with
MCERTS APPROVAL!


Click on MCERTS logo
for more information

Typical applications:
Monitoring NO, NO2 and SO2 Analysis from combustion process

The Pulsi 200LR series of instruments is designed for in stack analysis of up to six gas phase stack emission components.

Measurement principle: Dual wavelength infra-red principle    coupled with Enveloped Folded Beam
Fast response by direct in site measurement
Low maintenance
US EPA approval
CENELEC Hazardous area approval
 
 
 

   


 